Bruxton Logo

Parameters retrievable for QImaging cameras

Tag Value description
QImagingADCOffsetMaximum The maximum settable ADC offset value.
QImagingADCOffsetMinimum The minimum settable ADC offset value.
QImagingBlackoutOn Return value:
  1 indicates blackout mode is available
  0 (zero) indicates the blackout mode is not available.
QImagingCameraModeCount The number of total camera modes available.
QImagingCameraMode As input, the string variable supplies the index of the camera mode whose name will be returned. The index range is between zero and the return value of QImagingCameraModeCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingClearingModeCount The number of total clearing modes available.
QImagingClearingMode As input, the string variable supplies the index of the clearing mode whose name will be returned. The index range is between zero and one less than the return value of QImagingClearingModeCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingCooler Return value:
  1 indicates that the camera has a cooler
  0 (zero) indicates the camera does not have a cooler.
QImagingEMGainMaximum The maximum settable EM gain value.
QImagingEMGainMinimum The minimum settable EM gain value.
QImagingFanModeCount The number of total fan modes available.
QImagingFanMode As input, the string variable supplies the index of the fan mode whose name will be returned. The index range is between zero and one less than the return value of QImagingFanModeCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingHighSensitivityOn Return value:
  1 indicates the high sensitivity mode is available in the camera
  0 (zero) indicates the high sensitivity mode is not available.
QImagingImageFormatCount The number of total image formats available.
QImagingImageFormat As input, the string variable supplies the index of the image format whose name will be returned. The index range is between zero and one less than the return value of QImagingImageFormatCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingIntensifierGainMaximum The maximum settable intensifier gain value.
QImagingIntensifierGainMinimum The minimum settable intensifier gain value.
QImagingNormalizedGainMaximum The maximum settable normalized gain value.
QImagingNormalizedGainMinimum The minimum settable normalized gain value.
QImagingReadoutPortCount The number of total readout ports available.
QImagingReadoutPort As input, the string variable supplies the index of the readout port whose name will be returned. The index range is between zero and one less than the return value of QImagingReadoutPortCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingReadoutSpeedCount The number of total readout speeds available.
QImagingReadoutSpeed As input, the string variable supplies the index of the readout speed whose name will be returned. The index range is between zero and one less than the return value of QImagingReadoutSpeedCount. In IGOR 5 or later, there should be no input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingShutterCloseDelayMaximum The maximum settable close delay time in seconds for shutter.
QImagingShutterCloseDelayMinimum The minimum settable close delay time in seconds for shutter.
QImagingShutterOpenDelayMaximum The maximum settable open delay time in seconds for shutter.
QImagingShutterOpenDelayMinimum The minimum settable open delay time in seconds for shutter.
QImagingSyncBModeCount The number of total sync B modes available.
QImagingSyncBMode As input, the string variable supplies the index of the sync B mode whose name will be returned. The index range is between zero and one less than the return value of QImagingSyncBModeCount. In IGOR 5 or later, there should be input value for the parameter. When the function returns, all possible choices will be returned in the value separated by semicolons (";"). For example, the value will be set to "0:value 0;1:value 1" when the function returns.
QImagingTriggerDelayMaximum The maximum settable trigger delay time in seconds.
QImagingTriggerDelayMinimum The minimum settable trigger delay time in seconds.